1-800-668-4437


EXPLOSION PROOF REGENERATIVE BLOWER (3 PHASE)
 Documents
- No Documents -
File # E10822
UL
 
File # 019467_0_000
(Class 4228-81)
CSA Group
 
  • UL/CSA compliant - Declarations of conformity on file
  • UL and CSA approved motor with permanently sealed ball bearings
  • For industrial applications
  • Limited stocks: Available while supplies last.

Specifications


Part #Model NumberPowerBlower Stage(s)Maximum AirFlowMaximum VacuumRecommended VRV setting
212779ASK41.5 HP1125 CFM>120" H2O80" H2O
Part #Voltage @60hzPhaseAmpsRecommended Amp Setting for OverloadInlet & Outlet FNPT ThreadBaldor Premium Efficiency
212779A230/460V34.6/2.3N/A1.5"CEM7018T
Part #XP Motor Class-GroupRPMNEMAWeight (Motor + Blower)Dimensions (Horizontal Mounting)Capable of Vertical Mounting
212779AI - D, II - F & G3450143TCN/AN/AYes




Performance Grid